Skip to content
Dieline Generator
Sheet 01-16 · Tissue boxScale: schematic · Unit mm

Folding cartons

Tissue box

Horizontal box for facial tissues and handkerchiefs: body with side seam, ends with glued closures (Seal End), dispensing opening in the top as a perforation (slot or rectangle) with a thumb notch. Dimensions: length × top width × height.

Opens the online editor with this template. Try it without payment details; export with Pro.

Dieline: Tissue box
Vector preview from the catalogue, default dimensions
Template
Tissue box
Category
Folding cartons
Dimension reference
Inside dimensions
Default dimensions
240 × 120 × 90 mm
Parameters
12
Version
v1
Template ID
carton.tissue

Dimensions and limits

Default dimensions of the template and the permitted range in mm.

DimensionDefaultRange
Length240 mm80–300 mm
Width120 mm60–200 mm
Height90 mm40–200 mm

Parameters of this construction

12 parameters with default value and limits, adjustable in the editor.

ParameterDefaultRangeNote
Glue flapglueFlap15 mm8–25 mmWidth of the glue flap used to glue the blank into a tube. The material requires a minimum width.
Glue flap angleglueFlapAngle12°0–20°Bevel at the ends of the glue flap; facilitates folding and erection.
Dust flap length (ratio)dustFlapRatio80 %50–95 %Dust flap length as a ratio of the available length.
Dust flap angledustFlapAngle20°0–45°Bevel of the dust flaps (also the ears on the mailer); larger angles prevent collisions during folding.
Dust flap reliefdustFlapReliefExpert2 mm1–5 mmDistance between dust flap and lid along the crease; at least the material thickness. The machine requires a minimum slot width.
Outer flapsealOuterFlap100 %50–100 %Depth of the outer flap as a proportion of the opening width; 100 % covers the entire opening.
Inner flapsealInnerFlap60 %30–100 %Depth of the inner flap as a proportion of the opening width. Outer and inner flaps must overlap by at least the material's minimum glue width (glue strip).
Opening shapetissueOpeningShapeslotslot · rectangleSlot (fully rounded ends) or rectangle with an 8 mm corner radius.
Opening lengthtissueOpeningLength60 %30–80 %Length of the dispensing opening as a proportion of box length; at least 5 mm remains to the end creases.
Opening widthtissueOpeningWidth35 %15–60 %Width of the dispensing opening as a proportion of box width; at least 5 mm remains to the side creases.
Tear tabtearTabonon / offSemicircular thumb notch at the top edge of the window; press in and tear out the window along the perforation.
Tear tab radiustearTabRadius8 mm4–20 mmRadius of the thumb notch; it lies on the straight section of the top edge and reaches at most halfway down the window.

Assembly

Pre-break the blank, glue the side seam inside, and flatten. Erect, fold in the dust flaps and inner flap at one end, and glue down the outer flap; fill and close the second end the same way. To open, press in the thumb notch and tear out the window along the perforation.

Reference note

Reference classification still pending

Labels such as “similar to FEFCO” or “ECMA family, unconfirmed” are for orientation only. The templates are our own constructions; an assignment to a standard code is unconfirmed and not a trademark claim.

Related templates

Customise the Tissue box in your browser

Set dimensions and material, review findings and export print-ready as PDF, SVG or DXF.

Open in editor